Brand Name :Lixian
Model Number :HZ-9514
Certification :CE/ISO
Place of Origin :China
MOQ :1 set
Payment Terms :L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability :300 sets /per month
Packaging Details :Standard export wooden case
Model :HZ-9514
Customized support :OEM, ODM, OBM
Origin :China
Power :Electronic
Application :Mask, Guaze Mask
MOQ :1 Set
Standards :ASTM F2101 - 19 , YY/T 0969-2013, Q/0212 ZRB003-2011
Warranty :1 year/12months
Payment method :L/C,T/T,D/A,D/P
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

HZ-9514 Bacterial Filtration Efficiency Tester (BFE)

Equipment Overview

It used to test the percentage of respirator material removed from the bacteria - containing suspended particles at a specified flow rate. The dual-air path sampling method improves the accuracy of sampling, which is applicable to the performance test of bacterial filtration efficiency of medical surgical masks by metrological verification departments, scientific research institutes, medical mask manufacturers and other relevant departments

Standardization

  • Q/0212 ZRB003-2011 Surgical mask Bacterial filtration efficiency (BFE) detector
  • YY0469-2004 Surgical mask Bacterial filtration efficiency (BFE) detector technical request
  • YY/T 0969-2013 Standard for bacterial detection of disposable medical masks
  • ASTMF2100 Performance specifications of materials for medical masks
  • ASTM F2101 - 19 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials
  • EN 14683-2014 Medical face masks - Requirements and test methods

Technical Parameters

Main Parameter Parameter Range Resolution Max Error
A Sampling rate 28.3L/min 0.1L/min Exceed±2.5%
B Sampling rate 28.3L/min 0.1L/min Exceed±2.5%
Spray flow (8~10)L/min 0.1L/min Exceed±5.0%
Peristaltic pump flow (0.006~3.0)mL/min 0.001ml/min Exceed±2.5%
A Flowmeter front pressure (-20~0)kPa 0.01kPa Exceed±2.5%
B Flowmeter front pressure (-20~0)kPa 0.01kPa Exceed±2.5%
Spray flowmeter front pressure (0~300)kPa 0.1kPa Exceed±2.5%
Air chamber negative pressure (-90~-120)Pa 0.1Pa Exceed±2.0%
operating temperature (0~50)℃
Negative pressure (-50~-200)Pa
Data storage capacity >100000 groups
Characteristics of High Efficiency Air Filter The filtration efficiency of particles above 0.3um is ≥99.99%
Median mass diameter of aerosol generator Mean Corpuscular Diameter(3.0±0.3)μm, geometric standard deviation≤1.5
Dual channel 6 - stage Anderson sampler captures particle size Ⅰclass>7μm,Ⅱclass(4.7~7)μm,Ⅲ class(3.3~4.7)μm,Ⅳclass(2.1~3.3)μm,Ⅴ class(1.1~2.1)μm,Ⅵclass(0.6~1.1)μm
Aerosol chamber specifications (Length600×Dia85×Thickness 3)mm
Total number of particles in positive quality control sampler (2200±500)cfu